Greenville Heating & Cooling Reviews

Local Reviews
for Greenville, WI

Black-Haak Heating Rated 4.9 out of 5 stars based on 127 customer reviews
Mobile Tools for Contractors and Service Professionals Powered by Nearby Now

Map of Greenville, WI

Great Service and knowledgeable/friendly




Review of Black-Haak Heating

Would recommend


Map of Greenville, WI

On time and great customer service




Review of Black-Haak Heating


Map of Greenville, WI

He saved me from the odor from my service.




Review of Black-Haak Heating

Excellant service


Map of Greenville, WI

Great service




Review of Black-Haak Heating

A true professional.


Map of Greenville, WI

Great




Review of Black-Haak Heating

He was great


Map of Greenville, WI

Great




Review of Black-Haak Heating

Nice guy


Map of Greenville, WI

Great service and people




Review of Black-Haak Heating

Very knowledgeable, took time with me and never seemed rushed. Appreciate learning about additional services Black Haak provides. I will definitely use them. Also, as a bonus Dan is a huge animal lover and was so good with my crazy puppy. I have used Black Haak since 2002 and will continue as long as I have a home. Thank you!


Map of Greenville, WI

Technician was very polite and did a great job. He didn't even mind that my dog wouldn't leave him alone




Review of Black-Haak Heating


Map of Greenville, WI

Fall cleaning




Review of Black-Haak Heating


Map of Greenville, WI

Great Guy




Review of Black-Haak Heating

Anthony did a great job with our annual cleaning and maintenance on our HVAC system. He was attentive to my questions and concerns and did a great job explaining what he did and what he found during the service.


Brad G.

Brad G.

Inspected the pex compression fitting. I was able to tighten them up hopefully that stops the leak from the compression fitting. At some point the filling will fail and it will have to be replaced. Customer way want to think about updating current manifold to new ones. I can have the office pice that out for the customer if he us to. Thanks Brad

Near Terrace Dr, Greenville, WI 54942
Dan E.

Dan E.

Furnace clean and tune. Cycled system. Checked heat exchanger. Found some rusting and corrosion in all chambers. No visible cracks found with camera. Checked, removed, and cleaned burners and flame sensor. Both ok. Checked and tightened electrical connections and clamps. Cleared drain line. Checked and adjusted gas pressures to maximize efficiency. Igniter tested normal. Some evidence of igniter getting worn. Preformed combustion test. Found normal levels in exhaust. No CO found in airstream. Average life expectancy for this unit is 14 years. This system is showing signs of getting worn. Future failure is expected, but system is operating normal at this time. Job complete.

Near Rawley Point Dr, Greenville, WI 54942
Hunter D.

Hunter D.

Came out to check a fireplace. Customer said at times, the unit would light and then go out right away. When I got here, I had no issues with the fireplace lightening or staying lit. I cleaned the pilot as a preventative measure. Customer purchased a cleaning during my visit. We will call to schedule. Unit is heating properly.

Near Rivendale Ct, Greenville, WI 54942
Anthony N.

Anthony N.

Performed a preferred customer furnace cleaning. Cleaned the burners and the flame sensor. Checked the furnace heat exchanger. Wiped down the inside of the furnace. Checked the electrical. Cycled the furnace and performed a furnace combustion test. No issues with the furnace at this time.

Near Baileys Harbor Rd, Greenville, WI 54942
Anthony N.

Anthony N.

Was here for a furnace cleaning. Performed a furnace cleaning. Cleaned the burners and the flame sensor sensor. Checked the furnace heat exchanger. Wiped down the inside of the furnace. Checked the furnace electrical. Cycled the furnace. Performed a furnace combustion test. The furnace is running at this time. The furnace is 16 years old. The average life expectancy of a furnace is 15 years. Recommend replacing the furnace due to the age of the furnace. During the cleaning. Found that the transition assembly is cracked along the bottom and is leaking water in the furnace. The customer has a home warranty and will be submitting a claim.

Near Redwing Dr, Greenville, WI 54942
Dean P.

Dean P.

Completed gas furnace replacement. Disconnected and removed the old furnace and then set new one on blocks in its place. Reconnected the gas, electric, pvc venting and ductwork. Reconnected the existing Nest thermostat. Ran new drain hose for the AC coil and furnace to the floor drain location. Run tested the furnace but our office will contact you to schedule an appointment for one of our service technicians to come do a complete start up procedure at your convenience. Thank you for choosing Black-Haak Heating and Electric. Please take a moment to fill out our online survey.

Near Chapel Hill Dr, Greenville, WI 54942
Dan E.

Dan E.

Preformed furnace safety check. Cycled system. Checked and removed burners. All burners are extremely rusted and corroded. Major blockage from burners due to the damage. Checked and cleaned flame sensor. Ok. Igniter is showing signs of being worn. Checked heat exchanger with camera. Found all chambers are extremely rusted and corroded. Found crack in far right chamber. This is an automatic fail for safety inspection. This may cause CO to be vented into the home and is a safety issue. This should be corrected immediately for safety issues. Black-Haak heating not responsible for any issues if system started up by homeowner. Second opinion set for noon today. Nothing collected pending results of second opinion. Job complete.

Near Chapel Hill Dr, Greenville, WI 54942
Gary  P.

Gary P.

Cleaned flame sensor Cleaned gas burners Blew out drain lines and condensation trap Checked filter Checked inducer System working well Today

Near Goose Creek Cir, Greenville, WI 54942
Hunter D.

Hunter D.

Performed the level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger has minor rust. Combustion readings were normal. No CO detected in the air. Drain is clear. High limit passed the safety check. Heat rise was 52°. Unit is heating properly. I was smelling gas by the furnace. I did a courtesy leak search and found the union fitting by the furnace leaking. I shut off the gas to the furnace and took the union apart. I tightened everything down and put the piece back together. I leak checked the fittings again and had no more indication of a leak and the smell was gone.

Near Heavenly Dr, Greenville, WI 54942
Anthony N.

Anthony N.

Previously paid on other invoice. Performed a preferred customer furnace cleaning. Cleaned the burners and the flame sensor. Checked the furnace heat exchanger. Wiped down the inside of the furnace. Checked the electrical. Cycled the furnace and performed a furnace combustion test. No issues with the furnace at this time.

Near Daniel Ct, Greenville, WI 54942
Anthony N.

Anthony N.

Performed preferred customer furnace cleaning on 2 furnaces. Cleaned the burners and the flame sensor on both units. Wiped out the inside of the furnace. Checked the electrical. Cycled the furnaces and performed a furnace combustion test. The furnaces are both running normally at this time.

Near Daniel Ct, Greenville, WI 54942
Mark P.

Mark P.

Installed gas furnace

Near Redwing Dr, Greenville, WI 54942
Hunter D.

Hunter D.

Came out to investigate a smell from the fireplace. I did a gas leak search and didn’t find anything. Fireplace cycled fine. I did a curtesy check in the furnace and I found the venter motor had failed along with the heat exchanger. The failed heat exchanger likely let the smell into the air. I had to shut down the furnace. We will be in touch to quote options.

Near Redwing Dr, Greenville, WI 54942
Erika  J.

Erika J.

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter Inspected and tested inducer motor and blower motor Checked your condensate drain trap Furnace working well at this time. Please renew tuneups to maintain your warranty

Near Summer Wind Ln, Greenville, WI 54942
Anthony N.

Anthony N.

Performed a preferred customer fireplace cleaning. Wiped down and vacuumed the fireplace. Replaced the embers. Cleaned the fireplace glass. Tested the fireplace. Checked for carbon monoxide in the air stream. Found none at this time. No issues the fireplace at this time.

Near Highgreen Dr, Greenville, WI 54942
Hunter D.

Hunter D.

Performed the new furnace start up. No gas leaks detected. Combustion readings were normal. No CO detected in the air. Drain is working. High limit passed the safety check. Heat rise was 40°. I adjusted gas pressures and fan speeds for better comfort and efficiency. Unit is heating properly.

Near Hot Springs Ct, Greenville, WI 54942
Hunter D.

Hunter D.

Performed the level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger has some rust. No CO detected in the air. Drain is clear. High limit passed the safety check. Heat rise was 43°. Unit is heating properly.

Near Glen Valley Dr, Greenville, WI 54942
Anthony N.

Anthony N.

Performed a preferred customer furnace cleaning. Cleaned the burners and the flame sensor. Checked the furnace heat exchanger. Wiped down the inside of the furnace. Checked the electrical. Cycled the furnace and performed a furnace combustion test. No issues with the furnace at this time.

Near Buman Way, Greenville, WI 54942
Dan E.

Dan E.

Furnace clean and tune. Cycled system. Checked heat exchanger. Found minimal rusting and corrosion in chambers. Checked, removed, and cleaned burners and flame sensor. Burners and flame sensor are in working order. Checked electrical connections and clamps. Checked gas pressures. Ventor motor bearings appear to be in working order. Preformed combustion test and found normal levels. No CO found in airstream. System operating normal at this time. Job complete.

Near Schroeder Farm Dr, Greenville, WI 54942
Dan E.

Dan E.

Installed new aprilaire 600 humidifier. Removed old unit and wiring. Installed new unit. Ran new wiring to control from new unit. Installed new control and outdoor sensor. Wired into furnace. Installed new transformer wired into L1 L2. Installed new drain line from humidifier. Cycled system several times, operating normal at this time. Furnace clean and tune. Cycled system. Unit has a very hard light off. Checked heat exchanger, all chambers are extremely rusted and corroded. Cracks starting to form in two of the chambers. Checked, removed, and cleaned burners and flame sensor. All burners are very damaged and corroded. This is causing the flame to balloon out and fdamafe the heat exchanger near the front heat shield. Found rusting throughout the burner compartment. Cleaned flame sensor. Igniter tested lower, but within normal range. Ventor motor bearings are very worn and will seize at any time. Preformed combustion test and found levels higher than normal. This indicates clogs in the

Near Cedar Grove Ct, Greenville, WI 54942
Hunter D.

Hunter D.

Performed the new furnace start up. No gas leaks detected. Combustion readings were normal. No CO detected in the air. Drain is working. High limit passed the safety check. Heat rise was 33°. Unit is heating properly.

Near Meadowview Dr, Greenville, WI 54942
Erika  J.

Erika J.

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter Inspected and tested inducer motor and blower motor Furnace working well at this time. Please renew tuneups to maintain your warranty

Near Glen Rose Ln, Greenville, WI 54942
Kody W.

Kody W.

I found the transformer for the fireplace failed. We also tested the battery back up for the control and found this failed as well. Both parts need to be replaced. I replaced the transformer and the control for the fireplace. I cycled the fireplace. It’s working properly now.

Near Topaz Ct, Greenville, WI 54942
Hunter D.

Hunter D.

Performed the new furnace start up. No gas leaks detected. Combustion readings were normal. No CO detected in the air. Drain is working. High limit passed the safety check. Heat rise was 41°. Unit is heating properly. Customer said they didn’t think the make up air unit was working. I opened it up and found it was very dirty. We will schedule a cleaning and return to perform the cleaning and troubleshoot if necessary. It didn’t run during my visit. I quoted $44.95 for the cleaning.

Near Bluebluff Way, Greenville, WI 54942
Hunter D.

Hunter D.

Performed the level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger has rust and chipping, no cracks located. No CO detected in the air. Drain is clear. Excessive air was a little high, indicating wear in the secondary heat exchanger. Recommended we return next year to monitor the situation. Unit is currently heating properly and safely. Due to age and condition, life expectancy cannot be guaranteed.

Near Highgreen Dr, Greenville, WI 54942

Please give us a call at (920) 757-9990 for a free estimate. We look forward to serving you and please leave us a review!