Hortonville Heating & Cooling Reviews

Local Reviews
for Hortonville, WI

Black-Haak Heating Rated 4.9 out of 5 stars based on 69 customer reviews
Mobile Tools for Contractors and Service Professionals Powered by Nearby Now

Map of Hortonville, WI

Great Service




Review of Black-Haak Heating

Friendly, on time and very knowledgeable. They did an awesome job!


Map of Hortonville, WI

Annual Inspection of Our Home Heating System




Review of Black-Haak Heating

Gary Petrie was our service tech which in my opinion did an excellent job, communicated well, well mannered and conscience of our surroundings. I wouldn't mind having him come back every year to service our equipment!


Map of Hortonville, WI

Very polite and considerate of property will doing work.




Review of Black-Haak Heating


Map of Hortonville, WI

Very polite and considerate of property will doing work.




Review of Black-Haak Heating


Map of Hortonville, WI

Always a good experience




Review of Black-Haak Heating

All my experiences with Black Hawk have been very good. Service is timely, well done, generally well explained and service people always courteous.


Map of Hortonville, WI

Great service




Review of Black-Haak Heating

Kody is always great


Map of Hortonville, WI

Generator service & valve lash adjustment




Review of Black-Haak Heating

Punctual. Friendly, knowledgeable. Happy to have me look over his shoulder (to learn). Highly recommended.


Map of Hortonville, WI

Great Company




Review of Black-Haak Heating


Map of Hortonville, WI

Great service




Review of Black-Haak Heating

Dan did a excellent job. He was very professional and a really nice guy. And very helpful.


Map of Hortonville, WI

Electrical Service - Great!




Review of Black-Haak Heating

I have used your electrical services twice. Both times your electricians have been great. All work has been well done and timely efficient.


Hunter D.

Hunter D.

Delivered the filter. No answer. I left the filter at the door.

Near E Cedar St, Hortonville, WI 54944
Hunter D.

Hunter D.

Performed the level 2 furnace cleaning. Burners and flame sensor had a lot of oxidation to clean off. Igniter ohmed a little high. Heat exchanger has a lot of rust, however, no cracks located at this time. Combustion readings were normal. No CO detected in the air. Drain is clear. High limit passed the safety check. Heat rise was 53°. Unit is heating properly at this time. Due to age and condition, I recommended keeping an open mind for options in the future. Life expectancy cannot be guaranteed.

Near S Nash St, Hortonville, WI 54944
Gary  P.

Gary P.

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter looks like you order your own Inspected and tested inducer motor and blower motor Checked your condensate drain trap found multiple bugs in trap Furnace working well at this time Tune ups maintain warranty

Near Sandy Ln, Hortonville, WI 54944
Dan E.

Dan E.

Performed a preferred customer furnace cleaning on the attic furnace. Cleaned the burners and the flame sensor. Checked the furnace heat exchanger. Wiped down the inside of the furnace. Checked the electrical. Cycled the furnace and performed a furnace combustion test. No issues with the furnace at this time. Basement furnace. Cycled system. Checked heat exchanger, minimal rust and corrosion. Checked and cleaned burners and flame sensor. Checked and adjusted gas pressures to maximize efficiency. Preformed combustion test. All readings were normal. No CO in airstream. Replaced filter. System operating normal at this time. Guest house furnace. Cycled system. Checked heat exchanger, ok. Checked and cleaned burners and flame sensor. Checked and adjusted gas pressures to maximize efficiency. Checked and cleared drain line. Preformed combustion test and found all levels normal. No CO in airstream. Recommend replacing filter on this unit. Job complete. Customer is interested in using MR POW

Near Lakeview Ct, Hortonville, WI 54944
Brennan L.

Brennan L.

Repair leak. Chiseled more of the concrete out to repair pipe. Cut out punctured section of pipe and repaired with coupling. Pressure tested system. No leaks were found. Ran and tested boiler. All systems operating properly at this time. Thanks, Brennan and Brad

Near Roena Ln, Hortonville, WI 54944
Hunter D.

Hunter D.

Replaced the T4 thermostat. Cycled the furnace. Unit is heating properly.

Near County Rd M, Hortonville, WI 54944
Erika  J.

Erika J.

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter Inspected and tested inducer motor and blower motor Furnace working well at this time. Please renew tuneups to maintain your warranty

Near R and D Rd, Hortonville, WI 54944
Jamie  L.

Jamie L.

Quoted pricing Will call to schedule

Near Midway Rd, Hortonville, WI 54944
Craig W.

Craig W.

Completed gas piping and venting customer installed unit heater. Ran 3/4” black pipe from outside building into the attic, then changed to 1/2” Flashshield. Ran the Flashshield to a termination plate at ceiling adjacent to the heater. Ran a 4” RV pipe out through the roof and terminated it with a flashing, storm collar and cap. Connected the vent pipe to the heater. Thank you for choosing Black-Haak Heating and electric. Please take a moment to fill out our online survey.

Near Rock Rd, Hortonville, WI 54944
Hunter D.

Hunter D.

Performed the new furnace start up. No gas leaks detected. Combustion readings were normal. No CO detected in the air. Drain is working. High limit passed the safety check. Heat rise was 25°. Unit is heating properly. I also replaced the nozzle for the aprilaire humidifier.

Near Lakeview Ave, Hortonville, WI 54944
Kody W.

Kody W.

I was here to diagnose the furnace problems. I checked the intake and exhaust pipes for any blockage. Both were clear. I checked the drain trap. It was dirty. I cleaned the drain trap. I blew out all the pressure tubing and ports. I drained water out of the ventor motor. I cycled the furnace. The furnace would shutdown after a couple minutes and it wasn’t draining water. I replaced the ventor motor. I cycled the furnace. The furnace and thermostat are operating properly at this time.

Near R and D Rd, Hortonville, WI 54944
Jeremiah M.

Jeremiah M.

I installed the gateway. I connected via red link to the prestige thermostat. We set up the Honeywell app and verified access to the thermostat.

Near Roena Ln, Hortonville, WI 54944
Anthony N.

Anthony N.

Performed a preferred customer furnace cleaning. Cleaned the burners and the flame sensor. Checked the furnace heat exchanger. Wiped down the inside of the furnace. Checked the electrical. Cycled the furnace and performed a furnace combustion test. No issues with the furnace at this time.

Near N Nash St, Hortonville, WI 54944
Anthony N.

Anthony N.

Performed a preferred customer furnace cleaning. Cleaned the burners and the flame sensor. Checked the furnace heat exchanger. Wiped down the inside of the furnace. Checked the electrical. Cycled the furnace and performed a furnace combustion test. No issues with the furnace at this time.

Near Whitney St, Hortonville, WI 54944
Erika  J.

Erika J.

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked and changed filter Inspected and tested inducer motor and blower motor Furnace working well at this time. Please renew tuneups Could not install Honeywell t6 WiFi with humidistat zone board (removed charges) Follow up with Dan Fox to produce new wiring diagram (see photos) Customer needs this installed within 20 days

Near Roena Ln, Hortonville, WI 54944
Hunter D.

Hunter D.

Came out to investigate a no heat. Furnace was going out on a pressure fault. When I took the door off, the furnace would run fine. I cleared out all drains and hoses. I also checked what I could see in the venting and didn’t see anything blocking the way. I put the door back on and pulled off the intake pipe. The furnace ran fine when I did this. There’s possibly something clogging the intake pipe that we can’t see. The furnace is safe to operate without the pipe on. We will quote pricing to open up the pipe and check for obstruction. The reason for the thermostat saying “leave” is the thermostat was put into a schedule and the time zone it was currently in was the “leave” hours. I reset it back to permanent hold at 65°. Customers may reset it to wherever they prefer.

Near R and D Rd, Hortonville, WI 54944
Hunter D.

Hunter D.

Performed the level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger looks good. Combustion readings were normal. No CO detected in the air. Drain is clear. Heat rise was 56°. Unit is heating properly. I checked the fireplace and found the pilot wasn’t staying lit. I cleaned it with a wire brush and scotch pad with no success. The pilot assembly is bad and needs to be replaced. We will call with a quote. I waived the fireplace cleaning for now because I wasn’t able to perform it with a down unit.

Near Clover Leaf Rd, Hortonville, WI 54944
Erika  J.

Erika J.

Removed original inducer motor Wire brushed rusted area on furnace Installed new gasket Installed new inducer motor Retrofitted power terminals to new motor Reinstalled pressure switch Tested inducer Walk through with homeowner Completed

Near Giese St, Hortonville, WI 54944
Brad G.

Brad G.

Furnace not heat Ventor motor runs but pilot won’t start. Cycled the system and checked voltage at pressure switch. Pressure switch was open so I removed the exhaust and intake. Found a nest of some kind on top of the burner box. Once I removed it the unit stated up and ran. Talked to the customer about the age of the unit, 19 years old, and offered to come back for a cleaning. System is operating properly at this time. They are thinking about replacing the unit next year. Thanks Brad If you could take a few minutes and fill out a quick survey on how I did today I would greatly appreciate it.

Near Majestic View Ln, Hortonville, WI 54944
Brad G.

Brad G.

Customer said said the furnace wouldn’t lite and not run when I arrived I put the doors back on and started up the furnace. Furnace started up and ran cycled it a few time and couldn’t find any issues. Talked to the customer about the possible problems and highly suggested a cleaning. This way we can go through the unit and check over everything. Customer is going with the cleaning and they want to upgrade the thermostat. They will pay the balance of the bill when we do the cleaning and thermostat change. Thanks Brad If you could take a few mins and fill out a quick survey on how I did today I would greatly appreciate it.

Near Nye St, Hortonville, WI 54944
Hunter D.

Hunter D.

Performed the level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger has rust spots. Combustion readings were normal. No CO detected in the air. Drain is clear. Heat rise was 57°. Unit is heat properly.

Near Mayflower Rd, Hortonville, WI 54944
Hunter D.

Hunter D.

Performed the new furnace start up. No gas leaks detected. Combustion readings were normal. No CO detected in the air. Drain is working. High limit passed the safety check. Heat rise was 54°. Unit is heating properly.

Near Greenbrier Dr, Hortonville, WI 54944
Kody W.

Kody W.

Performed geo unit clean and tune. I cleaned the drain. Checked the electrical connections. Inspected and tested the contactor and capacitor, both are weak, I recommend replacing them. Tested loopfield pressure, it was at 10 psi, I added pressure to it. Cycled the geo and all the zones. The geo is heating and all the zones are working. We will drop off new filters when we get them. We will also order the contactor and capacitor.

Near Black Otter Ct, Hortonville, WI 54944
Hunter D.

Hunter D.

Performed the level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger looks good. Combustion readings were normal. No CO detected in the air. Drain is clear. High limit passed the safety check. Heat rise was 50°. Unit is heating properly. Filter pack was left by the furnace.

Near N Nash St, Hortonville, WI 54944
Anthony N.

Anthony N.

Performed a preferred customer furnace cleaning. Cleaned the burners and the flame sensor. Checked the furnace heat exchanger. Wiped out the inside of the furnace. Checked the electrical. Cycled the furnace. Performed a furnace combustion test. No issues with the furnace at this time. office to bill the customer.

Near Maple Leaf Ct, Hortonville, WI 54944