Menasha Heating & Cooling Reviews

Local Reviews
for Menasha, WI

Black-Haak Heating Rated 4.9 out of 5 stars based on 112 customer reviews
Mobile Tools for Contractors and Service Professionals Powered by Nearby Now

Map of Menasha, WI

Great




Review of Black-Haak Heating

Absolutely fantastic!!! He was very helpful in explaining what he was doing and why he was doing it. He was very knowledgeable and he gave me great instructions for what I should look for going forward. Wonderful experience!


Map of Menasha, WI

Good




Review of Black-Haak Heating


Map of Menasha, WI

Awesome service




Review of Black-Haak Heating

Thorough and complete inspection with great customer service


Map of Menasha, WI

Excellent service




Review of Black-Haak Heating


Map of Menasha, WI

Great service !




Review of Black-Haak Heating

Nice , trustworthy, educated tech. Happy to leave him a great review !


Map of Menasha, WI

Friendly, kind, hard working




Review of Black-Haak Heating

fast, and friendly. He took his time to explain what he was gonna do and got right to work! So thankful for his expertise and for the heat ☺️


Map of Menasha, WI

Helpful and friendly




Review of Black-Haak Heating


Map of Menasha, WI

Awesome experience




Review of Black-Haak Heating


Map of Menasha, WI

Great service




Review of Black-Haak Heating


Map of Menasha, WI

Great service, good explanation of information.




Review of Black-Haak Heating


Gary  P.

Gary P.

Completed start up

Near Oakridge Ct, Menasha, WI 54952
Dan E.

Dan E.

1st year furnace clean and tune. Cycled system. Checked heat exchanger, ok. Checked, removed, and cleaned burners and flame sensor. Both ok. Checked and adjusted gas pressures to maximize efficiency. Cleared drain lines. Checked and tightened electrical connections and clamps. Preformed combustion test and found normal levels in exhaust. No co found in airstream. System operating normal at this time. Job complete.

Near Jefferson St, Menasha, WI 54952
Hunter D.

Hunter D.

Came out to investigate a no heat. I cycled the furnace and the igniter would glow, but the burners wouldn’t ignite. It tried again and the burners stayed lit for a second before kicking out. On the third attempt, the furnace ran fine for five minutes. Error light flashed six times indicating a flame failure. I cleaned the flame rod and checked the igniter, everything was okay. 24v going to the gas valve. I tapped the gas valve with a screw driver to loosen up any stuck bearings. It seems like the gas valve is starting to become faulty. For safe keeping, I cleared the drain and pressure hoses and checked the pressure switches and venting, all was clear. They said they will monitor the situation between now and the cleaning.

Near Lilac Rd, Menasha, WI 54952
Gary  P.

Gary P.

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter Inspected and tested inducer motor and blower motor Checked your condensate drain trap Repair recommended: Inducer motor is running on 1.1 amp. Motor max is 1.0 amp Issues of note: Burners and heat exchanger are excessively used and metal fatigue is showing Due to age of equipment repair is cost prohibitive and replacement is recommended Second opinion to be scheduled

Near Drum Corps Dr, Menasha, WI 54952
Dan E.

Dan E.

Furnace clean and tune. Cycled system. Checked heat exchanger, ok. Checked, removed, and cleaned burners and flame sensor. Checked and adjusted gas pressures to maximize efficiency. Checked and tightened electrical connections and clamps. Preformed combustion test. Found normal levels in exhaust. No CO in airstream. System operating normal at this time. Job complete.

Near Dutch Hollow, Menasha, WI 54952
Anthony N.

Anthony N.

Performed a furnace start up. Checked over the furnace installation. Cycled the furnace. Set the gas pressure and checked the fan speed. Performed a furnace combustion test. The furnace is running normally at this time.

Near Bonnie Dr, Menasha, WI 54952
Dan E.

Dan E.

Furnace clean and tune. Cycled system. Checked heat exchanger. Ok, checked, removed, and cleaned burners and flame sensor. Burners were rusted and corroded. Cleaned back to normal. Checked and tightened electrical connections and clamps. Found drain line clogged. Cleared. Found drain line is pitched slightly uphill. Recommend condensate pump to help drain line to not clog. Checked gas pressures. Preformed combustion test. Normal levels found in exhaust. No CO found in airstream. System operating normal at this time. Job complete. Replaced filter.

Near State St, Menasha, WI 54952
Anthony N.

Anthony N.

Performed a furnace start up. Checked over the furnace installation. Cycled the furnace. Set the gas pressure and checked the fan speed. The furnace is running normally at this time.

Near Harold Dr, Menasha, WI 54952
Dan E.

Dan E.

Furnace clean and tune. Cycled system. Checked heat exchanger. Found all chambers have rust and corrosion. Did not find cracks with the camera. Checked, removed, and cleaned burners and flame sensor. Both ok. Checked igniter. Tested ok, some signs of getting worn. Ok at this time. Checked and adjusted gas pressures to maximize efficiency. Checked and tightened electrical connections and clamps. Cleared drain lines. Found ventor motor and blower motor bearings showing signs of getting worn. This is causing more noise in the system. Found ventor motor is leaking water. This is causing a lot of rusting in the burner compartment. Also found there is rust damage in blower compartment. Transition assembly is damaged and should be replaced along with ventor motor. Preformed combustion test. Found normal levels in exhaust. No CO found in airstream. System is showing signs of getting worn, but operating normal at this time. Average life expectancy for this unit is 14 years. Future failure is ex

Near Wilson St, Menasha, WI 54952
Hunter D.

Hunter D.

Performed the level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger looks good. Combustion readings were normal. No CO detected in the air. Drain is clear. High limit passed the safety check. Heat rise was 53°. Unit is heating properly. We will call in the spring to schedule the AC cleaning.

Near Lilac Rd, Menasha, WI 54952
Gary  P.

Gary P.

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter Inspected and tested inducer motor and blower motor Checked your condensate drain trap Furnace working well at this time Igniter and inducer potentially on their last season Removed cPVC 90 from blower compartment Heavy water damage in furnace box As life expectancy of this furnace is 14years recommend replacement before further breakdown

Near Melissa St, Menasha, WI 54952
Dan E.

Dan E.

Furnace clean and tune. Cycled system. Removed burner assembly. Checked igniter system. No cracks found on igniter system. Cleaned burner and heat shield. Ok. Used camera to check heat exchanger. Found several areas of rusting and etching. No visible cracks found. Checked gas pressure. Checked blower motor. Cleaned filter. Found bearings that are getting worn in ventor motor. No CO found in airstream. Found filter is very deteriorated. Recommend replacement of filter. Office to follow up with pricing and schedule to deliver. Job complete. System operating normal at this time, but future failure is expected.

Near Bessie Ohalloran Ln, Menasha, WI 54952
Gary  P.

Gary P.

There are 2 furnaces at this location Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter and changed Inspected and tested inducer motor and blower motor Checked your condensate drain trap Furnaces working well at this time Preformed gas sniffer check on both system Tune ups maintain warranty

Near Park St, Menasha, WI 54952
Hunter D.

Hunter D.

Performed the level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger looks good. Combustion readings were normal. No CO detected in the air. Drain is clear. High limit passed the safety check. Heat rise was 41°. Unit is heating properly.

Near Tayco St, Menasha, WI 54952
Dan E.

Dan E.

Furnace clean and tune. Cycled system. Checked heat exchanger, ok. Checked, removed, and cleaned burners and flame sensor. Both ok. Checked and adjusted gas pressures to maximize efficiency. Checked and tightened electrical connections and clamps. Cleared drain lines. Preformed combustion test and found normal levels in exhaust. No CO found in airstream. Replaced AA water panel. System operating normal at this time. Job complete.

Near Gosling Way, Menasha, WI 54952
Hunter D.

Hunter D.

Performed the level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger looks good. Combustion readings were normal. No CO detected in the air. Drain is clear. High limit passed the safety check. Heat rise was 39°. Unit is heating properly.

Near Willow Ln, Menasha, WI 54952
Anthony N.

Anthony N.

Performed a preferred customer furnace cleaning. Cleaned the burners and the flame sensor. Checked the furnace heat exchanger. Wiped down the inside of the furnace. Checked the electrical. Cycled the furnace and performed a furnace combustion test. No issues with the furnace at this time.

Near Southfield Dr, Menasha, WI 54952
Dan E.

Dan E.

Furnace clean and tune. Cycled system. Checked heat exchanger. Found all chambers have rust and corrosion, but no visible cracks found with camera. Checked, removed, and cleaned burners and flame sensor. Both ok. Checked igniter. Tested ok. Checked and tightened electrical connections and clamps. Cleared drain lines. Checked and adjusted gas pressures to maximize efficiency. Preformed combustion test. Normal levels found in exhaust. No CO found in airstream. Ventor motor bearings are getting worn. System operating normal at this time. Job complete.

Near Cherrybark Cir, Menasha, WI 54952
Gary  P.

Gary P.

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked igniter Checked filter Checked your condensate drain trap Furnace operating but has the following issues: Inducer Transition has a leak and condensed water is leaking past the gasket, this needs replaced.

Near Lakeview Ln, Menasha, WI 54952
Corey J.

Corey J.

11/6 Recessed Lights In Lower Level Of Home 11/14emailed quote

Near Lakeshore Dr, Menasha, WI 54952
Gary  P.

Gary P.

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter Inspected and tested inducer motor and newer blower motor Checked your condensate drain trap Furnace is on its 13th heat season, average furnace to last 14 years Extensive corrosion inside primary heat exchanger detected Complete

Near Tracey St, Menasha, WI 54952
Hunter D.

Hunter D.

Replaced blower motor. Cycled furnace. Unit is heating properly.

Near 2nd St, Menasha, WI 54952
Anthony N.

Anthony N.

Performed a preferred customer furnace cleaning. Cleaned the burners and the flame sensor. Checked the furnace heat exchanger. Wiped down the inside of the furnace. Checked the electrical. Cycled the furnace and performed a furnace combustion test. No issues with the furnace at this time.

Near Depere St, Menasha, WI 54952
Gary  P.

Gary P.

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter and replaced Inspected and tested inducer motor and blower motor Checked your condensate drain trap Furnace working well at this time Tune ups maintain warranty

Near Winnebago Ct, Menasha, WI 54952
Hunter D.

Hunter D.

Performed the level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger has minor wear. Excessive air levels were a little high, however, nothing to be concerned about at this time. No CO detected in the air. Drain is clear. High limit passed the safety check. Heat rise was 52°. Unit is heating properly and safely at this time.

Near Lotus Trail, Menasha, WI 54952