Neenah Heating & Cooling Reviews

Local Reviews
for Neenah, WI

Black-Haak Heating Rated 4.9 out of 5 stars based on 208 customer reviews
Mobile Tools for Contractors and Service Professionals Powered by Nearby Now

Map of Neenah, WI

Great




Review of Black-Haak Heating

Very nice man


Map of Neenah, WI

Great service!




Review of Black-Haak Heating


Map of Neenah, WI

High Quality and Service




Review of Black-Haak Heating

We've used Black-Hawk for our home and investment property - they never disappoint and do a terrific job.


Map of Neenah, WI

Fast and friendly!




Review of Black-Haak Heating

Dan came a little early which was great. He did an excellent job explaining how the service went and was very helpful and friendly.


Map of Neenah, WI

Dry friendly and helpful service technician




Review of Black-Haak Heating

He was so thorough and explained everything he did for the best service of our furnace.


Map of Neenah, WI

Good Experience




Review of Black-Haak Heating

Dan was very friendly, explained everything clearly, offered additional services and generally made me feel good about using Black Haak.


Map of Neenah, WI

The tech did a great job




Review of Black-Haak Heating


Map of Neenah, WI

Great Service




Review of Black-Haak Heating

Hunter was on time, respectful of my house and did a fine job on the yearly maintenance of my furnace


Map of Neenah, WI

Great timely personable service




Review of Black-Haak Heating

Tech Gary was courteous & proficient. Just a routine cleaning that was done well & timely.


Map of Neenah, WI

Great service




Review of Black-Haak Heating

Black Haak has been right there for all my needs


Dan E.

Dan E.

Furnace clean and tune. Cycled system. Checked heat exchanger, ok. Burners were checked, removed and cleaned, checked flame sensor and igniter. Cleaned flame sensor. Igniter tested normal at this time. Checked and adjusted gas pressures to maximize efficiency. Preformed combustion test. Normal levels found in exhaust. No CO found in airstream. Checked and tightened electrical connections and clamps. Cleared drain line. System operating normal at this time. Fireplace clean and tune. Cycled system. Flames did not light. Removed and cleaned glass. Checked and cleaned ignition system. Cleaned walls, and under unit. Reassembled and cycled system. System fired normal and cycled normal. Found pilot light was also out. Both units operating normal at this time. Job complete.

Near Pepper Grass Ln, Neenah, WI 54956
Gary  P.

Gary P.

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter Inspected and tested inducer motor and blower motor Checked your condensate drain trap Furnace working well at this time Tune ups maintain warranty

Near Remington Rd, Neenah, WI 54956
Dan E.

Dan E.

Furnace clean and tune. Cycled system. Checked heat exchanger, ok. Checked, removed and cleaned burners and flame sensor. Both were corroded, but cleaned up ok. Checked and adjusted gas pressures to maximize efficiency. Checked and tightened electrical connections and clamps. Cleared drain line. Preformed combustion test and found normal levels in exhaust. No CO found in airstream. System operating normal at this time. Fireplace. Checked ignition system. Customer stated that system would not consistently fire when the switch was flipped. Found that the sparker is worn and was loose. It was too far from the other probe. This may cause the current not to pass across the probes. I closed the gap between the probes and system fired better. This is a temporary fix and this ignition system may completely break off. At that time we can quote replacement of ignition system. Customer decided to clean the glass herself. Did not charge for fireplace cleaning since none was done. Job complete.

Near W Prairie Creek Dr, Neenah, WI 54956
Gary  P.

Gary P.

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter Inspected and tested inducer motor and blower motor Checked your condensate drain trap Furnace working well at this time Tune ups maintain warranty

Near Mary Ln, Neenah, WI 54956
Dan E.

Dan E.

Cycled system. System did not light. Found pilot light out. Changed batteries in remote sensor, did not fire. Checked all connections. Tried to light pilot and gas was not coming out when pilot selection was placed. Recommend replacement of gas valve. Due to age and nature of this system recommended Darboy stone and brick. System not operating at this time.

Near Skyview Dr, Neenah, WI 54956
Mark P.

Mark P.

Install gas furnace

Near Maple Grove Dr, Neenah, WI 54956
Craig W.

Craig W.

Completed gas furnace replacement. Disconnected and removed the old furnace. Set new furnace on blocks and reconnected the gas, electric, pvc venting and ductwork. Installed a new thermostat and connected it to the new furnace. Ran new hose to the floor drain for the furnace and AC condensate drains. Run tested the furnace but our office will contact you to schedule an appointment where one of our service technicians can come and do a complete start up procedure. Thank you for choosing Black-Heating and Electric. Please take a moment to fill out our online survey.

Near Edgewood Dr, Neenah, WI 54956
Hunter D.

Hunter D.

Performed the level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger looks good. Combustion readings were normal. No CO detected in the air. Drain is clear. High limit passed the safety check. Heat rise was 52°. Unit is heating properly.

Near Whitetail Dr, Neenah, WI 54956
Gary  P.

Gary P.

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter - filter changed Inspected and tested inducer motor and blower motor Checked your condensate drain trap Furnace working well at this time Tune ups maintain warranty

Near Alpha Dr, Neenah, WI 54956
Gary  P.

Gary P.

System coded out on roll out limit. After being cleared the system came on and during ignition proceeded to shoot flame out the front of the furnace. Checked air intake - good Checked flue - good Gas pressure set to 3.48. Good System flame still rolls back. Primary heat exchanger is plugged up and possible the secondary also Parts recommend for replacement 1. Primary heat exchanger 2. Secondary heat 3. Igniter needs replaced as the roll back has melted the ignition wires 4. Inducer motor is rusting away Customer to have 2nd opinion with Dan Fox to discus repair v replacement

Near Edgewood Dr, Neenah, WI 54956
Hunter D.

Hunter D.

Performed the new furnace start up. No gas leaks detected. Combustion readings were normal. No CO detected in the air. Drain is working. High limit passed the safety check. Heat rise was 49°. I replaced the broken door latch. Unit is heating properly.

Near Wallace Avenue, Neenah, WI 54956
Hunter D.

Hunter D.

Performed the level 2 furnace cleaning. I cleaned the burners and pilot. I found the heat exchanger had a lot of rust and chipping. Excessive air levels were a little high as well. Average life of system is 12-15 years. Unit is currently 30+ years of age. Parts will be very difficult to find in the event of a breakdown. Due to age and condition, I recommended a second opinion to go over options.

Near 5th St, Neenah, WI 54956
Hunter D.

Hunter D.

Performed the level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger is very rusty, however, no cracks located at this time. Excessive air was a little high, indicating wearing in the secondary heat exchanger. No CO detected in the air. Drain is clear. High limit passed the safety check. Heat rise was 49°. Unit is heating properly.

Near Woodhaven Ln, Neenah, WI 54956
Gary  P.

Gary P.

Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked flame sensor Checked filter Inspected and tested inducer motor and blower motor Checked your condensate drain trap Furnace working well at this time Tune ups maintain warranty

Near Klompen Ct, Neenah, WI 54956
Erika  J.

Erika J.

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter Inspected and tested inducer motor and blower motor Checked your condensate drain trap Furnace working well at this time. Please renew tuneups to maintain your warranty

Near Cavalry Ln, Neenah, WI 54956
Hunter D.

Hunter D.

Came out to investigate a no heat. Ignition would light but the blower wouldn’t kick in. Motor was very warm to the touch and I had voltage from the board. Blower motor bearing are worn out. Average life of system is 12-15 years. Furnace is currently 20+ years old. Due to age, condition, and cost for repairs, second opinion is recommended. Dan Fox will be calling later to quote. Customers are still without heat. Call Awilda with questions.

Near Shady Ln, Neenah, WI 54956
Craig W.

Craig W.

Completed gas furnace replacement. Disconnected and removed the old furnace. Set the new furnace on blocks and reconnected the gas, electric, pvc venting and ductwork. Installed a new T6 WiFi thermostat and ran new wire for it to the furnace. Reconnected the humidifier wiring and ran new drain hose for the furnace, AC and humidifier. Run tested the furnace but we will still have a technician come and do a complete start up procedure at your convenience. When the case of filters you requested come in, we will also drop them off for you. Thank you for choosing Black-Haak Heating and a Electric. Please take a moment to fill out our online survey.

Near Silverwood Ln, Neenah, WI 54956
Erika  J.

Erika J.

Replaced igniter for customer Customer had spare igniter- no warranty on igniter as Dan Fox

Near Shreve Ln, Neenah, WI 54956
Craig W.

Craig W.

Completed gas furnace replacement. Disconnected and removed the old furnace and set the new furnace on blocks in its place. Reconnected the gas, electric, pvc venting and ductwork. Installed a new T6 Wifi thermostat and connected it to the furnace. Run tested the furnace, but our office will contact you to schedule a time one of our service technicians can come and do a full start up procedure at your convenience. Thank you for choosing Black-Haak Heating and Electric. Please take a moment to fill out our online survey.

Near Chatham Ct, Neenah, WI 54956
Dan E.

Dan E.

Furnace clean and tune. Cycled system. Checked heat exchanger. Found both chambers rusted and corroded. No visible cracks found with camera. Blower motor is strained and bearings are getting worn. Checked and cleaned burners and flame sensor. Both ok. Checked and adjusted gas pressures to maximize efficiency. Checked and tightened electrical connections and clamps. Found drain line loose and worn. Average life expectancy for this unit is 14 years. This unit is over that time period and worn. Future failure is expected. Job complete. Due to age and condition, second opinion is recommended.

Near Maple Grove Dr, Neenah, WI 54956
Kody W.

Kody W.

No heat. The furnace was blowing cold air. I checked the furnace for error codes. The furnace was locked out on an ignition problem. I cleaned the flame sensor and cycled the furnace. The flame wasn’t carrying across the burner. I removed the burners and cleaned them. Cycled the furnace. The furnace is heating at this time. I recommend having maintenance performed on the furnace.

Near Paynes Point Rd, Neenah, WI 54956
Hunter D.

Hunter D.

Performed the level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger looks good. Combustion readings were normal. No CO detected in the air. Drain is clear. High limit passed the safety check. Heat rise was 41°. Unit is heating properly. I also checked the fireplace. The pilot assembly lit on my first attempt and the fireplace kicked right in. I cycled the unit a few times and let it run for awhile without failure. Customer said it would’ve normally failed right away. I recommended a cleaning, customer declined but they will continue to monitor the situation.

Near Spike Ct, Neenah, WI 54956
Erika  J.

Erika J.

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter -needs filter Inspected and tested inducer motor and blower motor Checked your condensate drain trap Please renew tuneups to maintain your warranty Tech recommendations to home owner: Second opinion Inducer motor currently running at twice of targeted amp draw Hi x air. Please check Ac has leak.

Near Winnegamie Dr, Neenah, WI 54956
Dan E.

Dan E.

Furnace clean and tune. Cycled system. Checked heat exchanger. Found some rust and corrosion in all chambers. No cracks found with camera and heat exchanger did pass powder test. Checked, removed, and cleaned burners and flame sensor. Burners and sensor were both very rusted and corroded. Cleaned both to acceptable condition. Igniter tested ok with some signs of minimal wearing. Checked and tightened all electrical connections and clamps. Signs of small water leak found in burner compartment. This is minimal and looks to be old. No signs of current leaking. Some evidence of Ventor motor bearing ware due to slight vibration and noise from motor itself. It does appear minimal at this time, but this can change at any point to cause issues. Preformed combustion test and found normal levels in exhaust. No CO found in airstream. Average life expectancy for this unit is 14 years. This system is operating normal at this time. Job complete.

Near Eagle Feather Trail, Neenah, WI 54956
Dan E.

Dan E.

Furnace clean and tune. Cycled system. Checked heat exchanger. Found some rusting and corrosion in chambers. No visible cracks found with camera. Checked, removed, and cleaned burners and flame sensor. All burners and flame sensor were very corroded and rusted. Cleaned as best as I could. Checked igniter, some signs of getting worn, but tested ok at this time. Found both cabinets very dirty. Ventor motor has signs of bearings getting worn. Cleared drain line. Found some obstructions in line. Cleared as best as I could. Possible failure of Ventor motor in future. Preformed combustion test and found normal levels in exhaust. No CO found in airstream. Average life expectancy for this unit is 14 years. This system is 15 years old and showing signs of getting worn. Even though this system is testing normal at this time, future failure is expected. Job complete.

Near Oak Hollow Ln, Neenah, WI 54956

Please give us a call at (920) 757-9990 for a free estimate. We look forward to serving you and please leave us a review!